To check a hygrometer you need a humidity that stays put. Place the sensor under test next to a reference probe, wait for the chamber to settle, and compare the two readings. If the chamber drifts, the comparison means nothing. The TH Series generates steam outside the workroom and circulates air through it, so humidity and temperature stay steady at each point.
Many labs calibrate with the compact TH-50 or TH-80: a small workroom reaches each humidity point faster, takes less bench space, and holds a few sensors plus a reference probe.
For a humidity calibration chamber price, send your humidity points, temperature range and number of sensors per run, and LIB Industry will quote the right size and version.
Steady Humidity: 20% ~ 98% RH, ±2.5% RH
Small deviation lets readings settle at each calibration point.
Benchtop Option: TH-50 / TH-80 for Small Labs
50 L or 80 L workroom with the same humidity range, accuracy and sensors as the larger models. Fits a lab bench, and lockable castors make it easy to move.
Capacitive Humidity Probe and PT-100 Class A Sensor
Real-time display of temperature and humidity on the touch screen.
Even Airflow: Circulating Air Through the Workroom
Sensors on different shelves see the same conditions, so you can check several devices per run.
Clean Steam: External Stainless-Steel Evaporation Humidifier
Humidity is generated outside the workroom, with automatic water supply and purification for long holds.
Cable Hole: Φ50 / 100 / 200 mm
Run sensor leads and a reference probe through the wall without opening the door.
Data to Your PC: Ethernet and USB
Connect to local laboratory software and download test data.
Model | TH-100 | TH-225 | TH-500 | TH-800 | TH-1000 |
Internal Dimensions (mm) | 400×500×500 | 500×600×750 | 700×800×900 | 800×1000×1000 | 1000×1000×1000 |
Overall Dimensions (mm) | 900×1050×1620 | 1000×1140×1870 | 1200×1340×2020 | 1300×1540×2120 | 1500×1540×2140 |
Interior Volume (L) | 100 | 225 | 500 | 800 | 1000 |
Heat Load | 1000 W | ||||
Temperature Range | A: -20 ~ +150 ℃; B: -40 ~ +150 ℃; C: -70 ~ +150 ℃ | ||||
Temperature Fluctuation / Deviation | ±0.5 ℃ / ±2.0 ℃ | ||||
Humidity Range / Deviation | 20% ~ 98% RH / ±2.5% RH | ||||
Heating / Cooling Rate | 3 ℃/min / 1 ℃/min | ||||
Cooling System | Mechanical compression refrigeration; French TECUMSEH compressor; eco-friendly refrigerant | ||||
Heating Element | Nichrome heater | ||||
Humidifier / Water System | External isolation, stainless steel surface evaporation / automatic water supply with purification | ||||
Controller | Programmable color LCD touch screen, Ethernet connection | ||||
Temperature Sensor | PT-100 Class A | ||||
Safety Protection | Humidifier dry-combustion, over-temperature, over-current, refrigerant high-pressure, water shortage, earth leakage | ||||
Materials | Interior SUS304 stainless steel; exterior coated steel plate; polyurethane foam and insulation cotton | ||||
Observation Window | Interior lighting, double-layer silicone rubber sealing | ||||
Standard Configuration | 1 cable hole with plug; 2 shelves | ||||
|
|
|
| Automatic water inlet Automatic control of the water intake of equipment Achieve automated testing | PC Link Ethernet connect to PC for easy operation Match to the local laboratory software USB to download data | Temperature and Humidity Sensor PT-100 Class A sensor, real-time accurate detection and display of temperature and humidity changes
|
|
|
Place the sensors under test and a reference probe on the same shelf.
Set the humidity and temperature point on the touch screen.
Wait for conditions to settle.
Compare the readings and record any difference.
Repeat at the next point, for example 30%, 50%, 70% and 90% RH.
| Field | Typical devices | What you can do |
|---|---|---|
| Small calibration labs | Hygrometers, probes, data loggers | Check a few sensors at set points on the bench |
| Metrology and calibration labs | Hygrometers, humidity probes | Check readings at set humidity points |
| Instrument makers | Data loggers, transmitters | Verify sensors before shipment |
| Electronics | Devices with humidity sensors | Validate sensor response |
| Quality control | Process monitoring instruments | Periodic accuracy checks |
Installation, operator training and 24/7 English remote support. Every unit runs 72 hours at the factory, with CE, RoHS and ISO 9001 documents, a 36-month warranty, then lifetime technical support. Standard models ship within 7~15 days.
Ready to enhance your humidity calibration chamber? Contact our technical specialists at ellen@lib-industry.com for detailed specifications and application consultation. LIB'll help design the optimal solution for your metrology requirements.