Calibration Environmental Chamber

Calibration Environmental Chamber

LIB Industry's Calibration Environmental Chamber (TH Series) holds temperature and humidity at stable, known set points, so you can calibrate and verify sensors, instruments and electronic devices against a reference. Five sizes from 100 L to 1,000 L, with cold limits of -20, -40 or -70 ℃, heating to +150 ℃ and humidity from 20% to 98% RH.

Temperature Range: -20 / -40 / -70 ℃ to +150 ℃ (three versions)
Humidity Range: 20% ~ 98% RH (±2.5% RH)
Stability: ±0.5 ℃ fluctuation, ±2.0 ℃ deviation
Sensors: PT-100 Class A temperature sensor, capacitive humidity probe
Volume: 100 L ~ 1,000 L, custom sizes available
Documents: ISO 17025 calibration, CE, RoHS
Product Description

Calibration Environmental Chamber Manufacturer & Supplier: Stable Set Points for Sensor and Device Calibration

A calibration is only as good as the conditions it is done in. If the chamber drifts, the sensor you are checking looks wrong, or worse, looks right. The TH Series holds temperature within ±0.5 ℃ and humidity within ±2.5% RH, with a PT-100 Class A sensor and even air circulation, so reference readings and test readings are taken under the same conditions.

For a calibration environmental chamber price, send your temperature and humidity points, device size and quantity, and LIB Industry will quote the right size and temperature version.

Built for Stable Calibration Points

Steady Conditions: ±0.5 ℃ Temperature, ±2.5% RH Humidity
Small fluctuation lets readings settle, so each calibration point is repeatable.

PT-100 Class A Sensor: Real-Time Display
Accurate temperature detection with live display on the touch screen.

Even Airflow: Uniform Air Outlet and Circulation
Air spreads evenly through the workroom, so devices on different shelves see the same conditions.

Clean Humidity: External Stainless-Steel Evaporation Humidifier
Humidity is generated outside the workroom, with automatic water supply and purification for long, unattended holds.

Wide Range: Three Cold Limits to +150 ℃, 20% ~ 98% RH
Cover cold, ambient, hot and humid points with one chamber.

Cable Hole: Powered Devices and Reference Leads
A cable hole with plug lets you route device leads and reference probes through the wall.

Capacitive Humidity Probe: Fast, Stable RH Readings

A capacitive sensor measures relative humidity directly and responds quickly, so humidity points settle and hold for calibration.

Calibration Environmental Chamber Technical Parameters

Item

TH-100

TH-225

TH-500

TH-800

TH-1000

Internal Dimensions (mm)

400×500×500

500×600×750

700×800×900

800×1000×1000

1000×1000×1000

Overall Dimensions (mm)

900×1050×1620

1000×1140×1870

1200×1340×2020

1300×1540×2120

1500×1540×2140

Interior Volume (L)

100

225

500

800

1000

Heat Load

1000 W

Temperature Range

A: -20 ~ +150 ℃; B: -40 ~ +150 ℃; C: -70 ~ +150 ℃

Temperature Fluctuation / Deviation

±0.5 ℃ / ±2.0 ℃

Humidity Range / Deviation

20% ~ 98% RH / ±2.5% RH

Heating / Cooling Rate

3 ℃/min / 1 ℃/min

Cooling System

Mechanical compression refrigeration; French TECUMSEH compressor; eco-friendly refrigerant

Heating Element

Nichrome heater

Humidifier / Water System

External isolation, stainless steel surface evaporation / automatic water supply with purification

Controller

Programmable color LCD touch screen, Ethernet connection

Temperature Sensor

PT-100 Class A

Safety Protection

Humidifier dry-combustion, over-temperature, over-current, refrigerant high-pressure, water shortage, earth leakage

Materials

Interior SUS304 stainless steel; exterior coated steel plate; polyurethane foam and insulation cotton

Observation Window

Interior lighting, double-layer silicone rubber sealing

Standard Configuration

1 cable hole with plug; 2 shelves

Calibration Environmental Chamber Performance Details

5.webp

15.webp

pv5.webp

Water Re-circulation

Water purifier: mainly purification from water source to water tank.

Automatic water supply

Cooling system

Mechanical compression refrigeration system

French TECUMSEH compressor

Environmentally friendly refrigerant

Sensor

PT-100 Class A sensor, real-time accurate detection and display of temperature changes at 0.001 degrees.

b3.webp

b14.webp

FAQs on Calibration Environmental Chamber

Q1. Can I calibrate sensors in this chamber?

Yes, as a stable temperature and humidity source. Place the device and a reference probe on the same shelf and compare readings once conditions settle. For formal accredited calibration, use your reference standard and procedure.

Q2. Does the chamber come with a calibration certificate?
Yes. Calibration is provided, including ISO 17025 calibration. Tell LIB Industry the points you need checked.

Q3. Which temperature version do I need?
-20 ℃ for most calibration and reliability work, -40 ℃ or -70 ℃ if your points go lower.

Q4. What comes with the chamber?
Installation, operator training and 24/7 English remote support. Every unit runs 72 hours at the factory, with CE, RoHS and ISO 9001 documents, a 36-month warranty, then lifetime technical support. Standard models ship within 7~15 days.

Ready to Set Up Your Calibration Points?

Send LIB Industry your temperature and humidity points, device size and quantity. LIB Industry engineers will recommend the right chamber and send a detailed quotation.