Precision humidity control is necessary for environmental simulation in material testing. The Humidity Test Chamber offers specialised moisture conditioning without temperature interference to meet crucial testing needs for the electronics, pharmaceuticals, textiles and packaging sectors. Pure humidity testing equipment differs from mixed temperature-humidity systems in that it is concerned only with hygroscopic behaviour, moisture absorption rates and humidity related material deterioration. This product eliminates temperature variables, delivering cost-effective solutions for applications requiring constant ambient temperature with controlled relative humidity—from MSL classification to polymer water absorption analysis.
Item | TH-100 | TH-225 | TH-500 | TH-800 | TH-1000 |
Internal Size (mm) | 400×500×500 | 500×600×750 | 700×800×900 | 800×1000×1000 | 1000×1000×1000 |
External Size (mm) | 900×1050×1620 | 1000×1140×1870 | 1200×1340×2020 | 1300×1540×2120 | 1500×1540×2140 |
Volume | 100L | 225L | 500L | 800L | 1000L |
Temp Range | -20 / -40 / -70℃ to +150°C | ||||
Humidity Range | 20–98% RH | ||||
Temp Fluctuation/Deviation | ±0.5°C/±2.0°C | ||||
Humidity Deviation | ±2.5% RH | ||||
Ramp Rate | Heating: 3°C/min, Cooling: 1°C/min | ||||
Cooling System | Mechanical compression (TECUMSEH) | ||||
Controller | LCD touch screen + Ethernet | ||||
Water Supply | Automatic + purification system | ||||
Material | SUS304 inner / coated steel outer | ||||
Window | Double-layer glass + silicone sealing | ||||
Standard | 1× cable port, 2 shelves | ||||
|
|
|
Automatic water inlet Automatic control of the water intake of equipment Achieve automated testing | Explosion-proof system
Explosion-proof door and viewing window Equip with smoke detector and buzzer Water spray against fire | PC Link
Ethernet connect to PC for easy operation Match to the local laboratory software USB to download data |
|
|
Your humidity environmental chamber utilizes ultrasonic transducers generating 3~5μm cold mist from deionized water. This eliminates mineral deposits and organic contamination common with tap water systems. The atomization process operates without heating, preventing temperature drift and ensuring true humidity-only testing conditions.
Moisture stability requires zero air infiltration. Our humidity resistance test chamber incorporates:
· Double-layer silicone dual-seal design: Creates hermetic closure preventing atmospheric moisture exchange
· Magnetic auto-lock door mechanism: Ensures uniform gasket compression regardless of operator force
· Fiberglass insulation walls: Minimizes condensation and thermal bridging
· Optional dew point meter integration: Real-time monitoring detects air leakage and triggers automatic humidification compensation
For ultra-low humidity applications (5%~10%RH), nitrogen purge ports enable inert atmosphere conditioning.
Unlike vertical flow systems creating stratification, our perforated rear wall design draws air uniformly, reconditions it, and redistributes it laterally. This humidity simulation chamber architecture delivers exceptional spatial homogeneity—critical when testing multiple samples simultaneously.
Since 2012, Xi'an LIB Environmental Simulation Industry has delivered reliable humidity test solutions to customers in 60+ countries, including Apple, Intel, Mercedes-Benz, and BYD.
Our humidity test chambers support major testing standards, including:
• IPC/JEDEC J-STD-020 for semiconductor moisture sensitivity
• ISO 62 & ASTM D570 for water absorption testing
• ICH Q1A for pharmaceutical stability testing
• GB/T 1034 for material hygroscopicity evaluation
Each chamber is verified for reliable performance and audit-ready test data.
With service centers in Malaysia, Canada, UK, and USA, plus 24/7 technical support, we help customers reduce downtime worldwide.
Every chamber includes a 3-year warranty and lifetime maintenance service. Replacement is provided if warranty repairs cannot resolve issues.
From special dimensions to multi-zone humidity control, our ISO 9001-certified team provides solutions tailored to your testing requirements.
DI water systems and optional conductivity monitoring ensure stable humidity generation and long-term test accuracy.
Q: What's the difference between this and a temperature-humidity chamber?
A: This high product maintains ambient temperature while controlling only moisture—ideal when temperature isn't a variable.
Q: Can it achieve below 20%RH?
A: Standard models reach 20%RH. For lower levels, specify nitrogen purge option during order.
Q: How often does the ultrasonic transducer need replacement?
A: With deionized water, typically 5+ years. We supply spare parts globally within 48 hours.
Q: Is installation complicated?
A: Simply connect power and DI water supply. We provide video guidance and remote commissioning support.
Q: Does it comply with FDA 21 CFR Part 11?