LIB Industry supplies Accelerated Shelf Life Testing Equipment for evaluating the stability of products under different temperature and humidity conditions.
The TH Series Temperature Humidity Chambers provide programmable environmental conditions for accelerated aging, pharmaceutical stability studies, packaging evaluation, and material performance testing. Multiple chamber capacities and temperature configurations are available to accommodate different specimen sizes and testing requirements.
Model | TH-100 | TH-225 | TH-500 | TH-800 | TH-1000 |
Internal Dimension (mm) | 400*500*500 | 500*600*750 | 700*800*900 | 800*1000*1000 | 1000*1000*1000 |
Overall Dimension (mm) | 900*1050*1620 | 1000*1140*1870 | 1200*1340*2020 | 1300*1540*2120 | 1500*1540*2140 |
Interior Volume | 100L | 225L | 500L | 800L | 1000L |
Heat load | 1000W | ||||
Temperature Range | A: -20 to +150°C / B: -40 to +150°C / C: -70 to +150°C | ||||
Temperature Fluctuation / Deviation | ± 0.5 ℃ / ± 2.0 ℃ | ||||
Humidity Range | 20% ~ 98% RH | ||||
Humidity Deviation | ± 2.5% RH | ||||
Cooling Rate | 1 ℃ / min | ||||
Heating Rate | 3 ℃ / min | ||||
Cooling system | Mechanical compression refrigeration system,French TECUMSEH compressor | ||||
Heating Element | Nichrome heater | ||||
Controller | Programmable color LCD touch screen controller, Ethernet connection | ||||
Water supply system | Automatic water supply, Water purification system | ||||
Humidifier | External isolation, stainless steel surface evaporation humidifier | ||||
Safety device | Humidifier dry-combustion protection; over-temperature protection; over-current protection; Refrigerant high-pressure protection; Water shortage protection, Earth leakage protection; | ||||
|
|
|
Automatic water inlet Automatic control of the water intake of equipment Achieve automated testing | Air circulation The air is uniformly distributed through the air outlet Air circulates evenly throughout the workroom | Castors Install 4 castors for ease moving, and with brakes function. Caster height adjustable. |
|
|
Stable Conditions: ±0.5 ℃ Temperature, ±2.5% RH Humidity
Fluctuation stays small throughout long stability trials, so differences in your results come from the samples, not the chamber.
Clean Humidity: External Stainless-Steel Evaporation Humidifier
Humidification happens outside the workspace, with automatic water supply and a water purification system. This helps keep sensitive food and pharmaceutical samples free from contamination.
Fast Transitions: 3 ℃/min Heating, 1 ℃/min Cooling
Reach test conditions quickly and run programmed temperature steps.
Built for 24/7 Operation: TECUMSEH Compressor
A French TECUMSEH compressor and an environmentally friendly refrigerant support continuous long-term testing.
Even Airflow: Uniform Air Circulation
Air is distributed through the air outlet and circulates evenly through the workroom, so samples on different shelves see the same conditions.
Traceable Records: Ethernet Data Connection
The programmable touch screen controller connects by Ethernet for monitoring and data export, which supports audit preparation.
The Accelerated Shelf Life Testing Equipment can be configured for common pharmaceutical stability testing conditions specified in ICH Q1A(R2).
| Test Type | Temperature | Relative Humidity | Typical Study Period |
|---|---|---|---|
| Long-Term | 25°C ± 2°C | 60% RH ± 5% RH | 12 months minimum at submission |
| Long-Term Alternative | 30°C ± 2°C | 65% RH ± 5% RH | 12 months minimum at submission |
| Intermediate | 30°C ± 2°C | 65% RH ± 5% RH | 6 months |
| Accelerated | 40°C ± 2°C | 75% RH ± 5% RH | 6 months |
These are general ICH Q1A(R2) conditions for applicable drug substances and products. The study protocol, packaging type, and applicable regulatory requirements determine the actual test conditions. When 30°C/65% RH is selected as the long-term condition, a separate intermediate condition is not required.
The TH Series temperature and humidity range covers these common conditions. Actual compliance should be confirmed against the selected model's performance, calibration, and qualification requirements.
Q1. Which ICH conditions can the chamber run?
25 ℃/60% RH, 30 ℃/65% RH and 40 ℃/75% RH.
Q2. Which model and temperature version should I choose?
Choose by sample volume and lowest temperature. Version A (-20 ℃) is enough for shelf life tests above room temperature; choose B or C for cold storage or freeze-thaw.
Q3. How much does an accelerated shelf life testing chamber cost?
Price depends on model, temperature version and configuration. Send LIB Industry your requirements for a quotation.
Q4. What is the lead time and how is it shipped?
Standard models ship within 7~15 days, by sea, by air, or door-to-door.
Q5. Is installation, training and calibration provided?
Yes: installation, operator training and ISO 17025 calibration, plus 24/7 remote support in English.
Q6. Why buy a temperature humidity chamber from LIB Industry?
CE, RoHS, ISO 9001 and ISO 17025 calibration documents for audits
72-hour continuous test before every shipment
Service centers in Malaysia, Canada, the UK and the US
36-month warranty, then lifetime technical support