When you're testing how your materials will perform after a long time of open air presentation, exactness isn't optional—it's everything. Our UV Accelerated Machine conveys laboratory-grade weathering recreation that meets universal benchmarks, making a difference you anticipate item life expectancy with certainty. Whether you're in coatings, plastics, car, or building materials, this gear duplicates the harming impacts of daylight, dampness, and temperature in a controlled environment. Prepared with closed-loop irradiance control and condensation frameworks, the item guarantees your test information will be recognized all inclusive. You get repeatable comes about, speedier item advancement cycles, and the peace of intellect that comes from knowing your materials can withstand real-world conditions.
You're not buying equipment—you're buyingtest credibility.
Our weathering tester is designed to meet the most widely recognized global standards:
· ISO 4892-3– Plastics weathering (fluorescent UV method)
· ASTM D4329– Plastics in laboratories using fluorescent UV lamps
· ASTM D4587– Coatings exposed to fluorescent UV and condensation
· ASTM G154– General-purpose UV weathering (most cited standard worldwide)
· ISO 11507– Paints and varnishes
· SAE J2020– Automotive exterior materials
Whether you're supplying to European, North American, or Asian markets, this equipment ensures your test reports will be accepted by regulators, auditors, and customers.
Model | UV-SI-260 |
Internal Dimension (mm) | 450*1170*500 |
Overall Dimension (mm) | 610*1330*1470 |
Specimen Holder Size(mm) | 75*150 |
Specimen Capacity | 56 Pieces |
Irradiation Source | Fluorescent UV lamps (8) - 40 W |
Temperature Range | Ambient ~ 90 ℃ ±2℃ |
Black Panel Temperature (BPT) | 35 ~ 80 ℃ |
Humidity Range | ≥95% RH |
Bandwidth | 290 ~ 400nm |
Irradiance Control | 0.3~20 W/㎡ |
Water Spray Cycle | 1~9999H59M (Adjustable) |
Distance of Specimen and lamp | 50mm |
Controller | Programmable color LCD touch screen controller, Ethernet connection |
Water Supply System | Automatic water supply, Water purification system |
Safety Device | Over-temperature Protection; Over-current Protection; Water Shortage Protection; Earth leakage Protection; Phase Sequence Protection |
Exterior Material | Steel Plate with protective coating |
Interior Material | SUS304 stainless steel |
|
|
|
| Irradiation Source The chamber is equipped with total of 8 lamps, each 40W. Easy to change UV lamps | Controller PID programmable color touch screen controller Network connection computer. | Water Spraying Equipped with ten nozzles, the diameter of the nozzle is 0.5mm, the settlement is 0.8 ~ 1.0mm / 80cm2 / H |
|
|
Automatic irradiance control keeps UV intensity stable throughout testing by compensating lamp aging and voltage changes. No manual adjustment needed, ensuring consistent and internationally accepted results. UVA-340: Simulates natural sunlight (295–365 nm), for outdoor weathering tests UVB-313: Faster, more aggressive aging for rapid QC screening Lamp life: 5000 hours, easy replacement and predictable maintenance. Bottom-heated water system creates true condensation (100% humidity) to simulate dew exposure. Corrosion-resistant aluminum racks ensure stable sample positioning and uniform exposure. Since 2009, Xi'an LIB Environmental Simulation Industry has been trusted byApple, IBM, Intel, SGS, TUV, BYD, Great Wall Motors, and Mercedes-Benz. We're not just a manufacturer—we're asolutions providerwith service centers inMalaysia, Canada, the UK, and the USA. Every UV Accelerated Machine comes with a3-year warranty and lifetime service. If something goes wrong and we can't fix it during the warranty period, we'll replace the entire unit. You also get24/7 global technical supportvia phone, email, and remote diagnostics. Need a custom solution? Our engineering team specializes in non-standard designs. We'll work with you to adapt chamber size, lamp configuration, or control software to your exact requirements. Q: How often should I calibrate the irradiance sensor? A: We recommend calibration every 3–6 months, or per your internal SOP. Our system supports quick radiometer-based calibration. Q: Can I use tap water for condensation? A: No. Always use distilled or deionized water to prevent mineral deposits that can affect lamp performance and sample contamination. Q: What's the difference between UVA-340 and UVB-313 lamps? A: UVA-340 simulates natural sunlight (295–365 nm), ideal for realistic aging. UVB-313 uses shorter, harsher UV for faster comparison testing. Q: How long does a typical weathering test take? A: It depends on your standard and material. Common cycles range from 500 to 2,000 hours. Accelerated tests can replicate months or years of outdoor exposure. Q: Do you offer installation and training? A: Yes. We provide on-site installation, operator training, and digital manuals. Remote training via video call is also available. Our UV Accelerated Machine gives you the control, compliance, and confidence you need to bring durable products to market faster. Contact us:ellen@lib-industry.comWhy Choose LIB UV Accelerated Machine
① Closed-Loop Irradiance Control
One-touch radiometer calibration simplifies routine verification.② UV Lamp Options
③ Condensation & Spray Simulation
Supports programmable water spray cycles to simulate rain and thermal shock.Proven Global Service Network
Frequently Asked Questions (FAQ)
Get Started Today