Thermal Shock Chamber

Thermal Shock Chamber

LIB thermal Shock chamber is designed to provide rapid transitions between hot and cold temperature zones.2-zone and 3-zone thermal shock chambers are available.

Lower limit Temperature:-75℃

Upper limit Temperature:+220℃

Temperature Range:-70℃~+220 ℃

The specimen automatic transferred from cold chamber to hot chamber by basket

Temperature Recovery Time:Within 5 minutes

Refrigerant: Environmental refrigerant
Product Description

Semiconductor-Grade Thermal Shock Chamber with Precision Temperature Control

Thermal shock testing demands precision, reliability, and compliance with rigorous industry standards. A Thermal Shock Chamber is essential for validating product durability under extreme temperature cycling, particularly in semiconductor, automotive, aerospace, and electronics manufacturing. Xi'an LIB Environmental Simulation Industry is a professional manufacturer of high performance thermal shock test chamber for meeting the rigorous demands of semiconductor grade applications. We build equipment that manages temperature overshoot, transition speeds and long term structural integrity, so you can get accurate, repeatable test results, while decreasing your operating expenses and compliance concerns.

Specification of Thermal Shock Chamber

Model

TS-162

TS-340

TS-500

TS-1000

Internal Dimensions (mm)

300*300*250

450*450*360

650*650*500

850*850*700

Overall Dimension (mm)

1560*870*1545

1710*1020*1845

1910*1220*2265

2110*1420*2665

Interior Volume (mm)

22L

72L

211L

505L

Loading Capacity

20kg

30kg

50kg

60kg

Upper limit Temperature

+220℃

Heating Time

Ambient ~ + 200℃, within 30 minutes

Lower limit Temperature

-75℃

Cooling time

Ambient ~ -70℃, within 30 minutes

High Temperature  Exposure Range

Ambient +20 ~ +200°C

Low temperature Exposure Range

–65 ~ -5°C

Temperature Fluctuation

≤±0.5℃

Temperature Deviation

≤±3 ℃

Temperature Recovery Time

Within 5 minutes

Cooling System

Mechanical compression refrigeration system

Controller

Programmable color LCD touch screen controller, Ethernet connection

Safety Device

Over-temperature protection, Over-current protection; Refrigerant high-pressure protection; Earth leakage protection

Exterior Material

Steel Plate with protective coating

Interior Material

SUS304 stainless steel

Observation Window

Interior lighting, double-layer thermo stability silicone rubber sealing

Standard Configuration

2 shelves

Product Details

TS1.webp

b19.webp

b49.webp

Basket

The specimen automatic transferred from cold chamber to hot chamber by basket. The basket slides vertically and smoothly through rail.

Cooling system

Mechanical compression refrigeration system

French TECUMSEH compressor

Environmentally friendly refrigerant

Castors

Install 4 castors for ease moving, and with brakes function.

Caster height adjustable.

TS1.webp

TS3.webp

Why Choose Us

Precise Temperature Shock Control

LIB temperature shock chambers use advanced control technology to minimize temperature overshoot and maintain stable test conditions. The system provides accurate hot and cold zone switching for reliable thermal shock testing.

Fast Temperature Transfer Performance

The pneumatic basket system enables rapid transfer between high and low temperature zones, achieving temperature changes within ≤3 seconds and improving test efficiency for demanding applications.

Durable Structure & Thermal Stability

The chamber features SUS304 stainless steel construction for long-term high-temperature operation. Optimized insulation and anti-frost refrigeration design ensure stable performance during continuous testing while reducing energy consumption.

Global Support & 3-Year Warranty

Since 2012, LIB Industry has provided environmental test solutions to customers in 60+ countries. With global service support in the US, Canada, UK, and Malaysia, we provide:

  • 3-year warranty & lifetime service

  • 24/7 technical support

  • Replacement guarantee during warranty period if repair is impossible

Full Compliance with International Testing Standards

Our liquid thermal shock chamber and air-based systems are designed to meet:

· MIL-STD-883H Method 1011 – Thermal Shock (U.S. military semiconductor standard, global industry benchmark)

· JEDEC JESD22-A106 – Thermal Shock for chip packaging

· IPC-TM-650 Method 2.6.7 – Thermal Shock for PCB solder mask

· AEC-Q100 Rev-H – Failure Mechanism Based Stress Test (automotive chip reliability, OEM supplier qualification)

FAQ

Q: What is the difference between two zone and three zone the products?

A: Two zone systems use hot and cold compartments. Three zone systems add an ambient zone for more complex cycling profiles.

Q: How quickly can the chamber switch temperatures?

A: Basket transfer takes ≤3 seconds; recovery to setpoint ±5% takes ≤3 minutes.

Q: Is customization available for non-standard testing needs?

A: Yes. LIB specializes in custom R&D and non-standard design to meet your unique requirements.

Q: What maintenance is required?

A: Minimal. Hydrophilic evaporator fins resist frost buildup. Routine filter checks and annual calibration are recommended.